Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Am Soc Echocardiogr ; 36(12): 1302-1314, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37507058

RESUMO

BACKGROUND: The role of echocardiography in deriving transvalvular mean gradients from transaortic velocities in aortic stenosis (AS) and in structural valve degeneration (SVD) is well established. However, reports following surgical aortic valve replacement, post-transcatheter aortic valve replacement (TAVR), and valve-in-valve-TAVR (ViV-TAVR) have cautioned against the use of echocardiography-derived mean gradients to assess normal functioning bioprosthesis due to discrepancy compared with invasive measures in a phenomenon called discordance. METHODS: In a multicenter study, intraprocedural echocardiographic and invasive mean gradients in AS, SVD, post-native TAVR, and post-ViV-TAVR were compared, when obtained concomitantly, and discharge echocardiographic gradients were recorded. Absolute discordance (intraprocedural echocardiographic - invasive mean gradient) and percent discordance (intraprocedural echocardiographic - invasive mean gradient/echocardiographic mean gradient) were calculated. Multivariable regression analysis was performed to determine variables independently associated with elevated postprocedure invasive gradients ≥20 mm Hg, absolute discordance >10 mm Hg, and discharge echocardiographic mean gradient ≥20 mm Hg. RESULTS: A total of 5,027 patients were included in the registry: 4,725 native TAVR and 302 ViV-TAVR. Intraprocedural concomitant echocardiographic and invasive mean gradients were obtained pre-TAVR in AS (n = 2,418), pre-ViV-TAVR in SVD (n = 101), in post-ViV-TAVR (n = 77), and in post-TAVR (n = 823). Echocardiographic and invasive mean gradients demonstrated strong correlation (r = 0.69) and agreement (bias, 0.11; 95% CI, -0.4-0.62) in AS, moderate correlation (r = 0.56) and agreement (bias, 1.08; 95% CI, -2.53 to 4.59) in SVD, moderate correlation (r = 0.61) and weak agreement (bias, 6.47; 95% CI, 5.08-7.85) post-ViV-TAVR, and weak correlation (r = 0.18) and agreement (bias, 3.41; 95% CI, 3.16-3.65) post-TAVR. Absolute discordance occurs primarily in ViV-TVR and is not explained by sinotubular junction size and increases with increasing echocardiographic mean gradient. Percent discordance in AS and SVD (1.3% and 4%, respectively) was lower compared with post-TAVR/ViV-TAVR (66.7% and 100%, respectively). Compared with self-expanding valves, balloon expanding valves were independently associated with elevated discharge echocardiographic but lower invasive mean gradient (odds ratio = 3.411, 95% CI, 1.482-7.852, P = .004; vs odds ratio = 0.308, 95% CI, 0.130-0.731, P = .008, respectively). CONCLUSIONS: Post-TAVR/ViV-TAVR, echocardiography is discordant from invasive mean gradients, and absolute discordance increases with increasing echocardiographic mean gradient and is not explained by sinotubular junction size. Percent discordance is significantly higher post-TAVR/ViV-TAVR than in AS and SVD. Post-TAVR/ViV-TAVR, poor correlation and wide limits of agreement suggest echocardiographic and invasive mean gradients may not be used interchangeably and a high residual echocardiographic mean gradient should be confirmed invasively before considering any additional procedure to "correct" the gradient. Transcatheter aortic valve replacement valve types have variable impact on echocardiographic and invasive mean gradients.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Ecocardiografia
2.
JACC Cardiovasc Interv ; 15(18): 1837-1848, 2022 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-36137687

RESUMO

BACKGROUND: Low ejection fraction (EF) and low flow as determined by an echocardiographic stroke volume index (SVi) <35 mL/m2 are associated with low transvalvular gradients and increased mortality in both severe aortic stenosis (AS) and post-transcatheter aortic valve replacement (TAVR). Absence of an elevated echocardiographic transaortic gradient post-TAVR is considered a marker of procedural success despite the absence of data on its impact on mortality. OBJECTIVES: The authors sought to examine the association of invasive and echocardiographic gradients post-TAVR with all-cause mortality in relation to flow and EF. METHODS: In a multicenter retrospective registry of patients undergoing TAVR, Cox models with regression splines explored the relationship between invasive and echocardiographic gradients post-TAVR with 2-year mortality. An invasive gradient <5 mm Hg was considered low, between ≥5 and <10 mm Hg was considered intermediate, and ≥10 mm Hg was considered high. An echocardiographic gradient <10 mm Hg was considered low, ≥10 and <20 mm Hg was considered intermediate, and ≥20 mm Hg was considered high. RESULTS: Higher mortality occurred in low echocardiographic gradients at discharge relative to intermediate gradients (P < 0.001), and low gradient was associated with lower EF and echocardiographic SVi (P < 0.001 and P < 0.008, respectively). Lower mortality occurred in low invasive gradients relative to intermediate gradients (P = 0.012) with no difference in EF and echocardiographic SVi between groups (P = 0.089 and P = 0.947, respectively). There were insufficient observations to determine the impact of high echocardiographic and invasive gradients on mortality. CONCLUSIONS: In this large retrospective analysis, the impact of transaortic gradients on mortality after TAVR was not linear and complex, showing opposite results among echocardiographic and invasive measurements in low-gradient patients.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Humanos , Sistema de Registros , Estudos Retrospectivos , Índice de Gravidade de Doença , Volume Sistólico , Resultado do Tratamento
3.
N Engl J Med ; 387(14): 1253-1263, 2022 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-36121045

RESUMO

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) for the treatment of aortic stenosis can lead to embolization of debris. Capture of debris by devices that provide cerebral embolic protection (CEP) may reduce the risk of stroke. METHODS: We randomly assigned patients with aortic stenosis in a 1:1 ratio to undergo transfemoral TAVR with CEP (CEP group) or without CEP (control group). The primary end point was stroke within 72 hours after TAVR or before discharge (whichever came first) in the intention-to-treat population. Disabling stroke, death, transient ischemic attack, delirium, major or minor vascular complications at the CEP access site, and acute kidney injury were also assessed. A neurology professional examined all the patients at baseline and after TAVR. RESULTS: A total of 3000 patients across North America, Europe, and Australia underwent randomization; 1501 were assigned to the CEP group and 1499 to the control group. A CEP device was successfully deployed in 1406 of the 1489 patients (94.4%) in whom an attempt was made. The incidence of stroke within 72 hours after TAVR or before discharge did not differ significantly between the CEP group and the control group (2.3% vs. 2.9%; difference, -0.6 percentage points; 95% confidence interval, -1.7 to 0.5; P = 0.30). Disabling stroke occurred in 0.5% of the patients in the CEP group and in 1.3% of those in the control group. There were no substantial differences between the CEP group and the control group in the percentage of patients who died (0.5% vs. 0.3%); had a stroke, a transient ischemic attack, or delirium (3.1% vs. 3.7%); or had acute kidney injury (0.5% vs. 0.5%). One patient (0.1%) had a vascular complication at the CEP access site. CONCLUSIONS: Among patients with aortic stenosis undergoing transfemoral TAVR, the use of CEP did not have a significant effect on the incidence of periprocedural stroke, but on the basis of the 95% confidence interval around this outcome, the results may not rule out a benefit of CEP during TAVR. (Funded by Boston Scientific; PROTECTED TAVR ClinicalTrials.gov number, NCT04149535.).


Assuntos
Estenose da Valva Aórtica , Dispositivos de Proteção Embólica , Embolia Intracraniana , Implantação de Prótese , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Injúria Renal Aguda/etiologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Delírio/etiologia , Humanos , Embolia Intracraniana/etiologia , Embolia Intracraniana/prevenção & controle , Ataque Isquêmico Transitório/etiologia , Implantação de Prótese/instrumentação , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
4.
J Am Heart Assoc ; 10(19): e021014, 2021 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-34585593

RESUMO

Background Concerns about discordance between echocardiographic and invasive mean gradients after transcatheter aortic valve replacement (TAVR) with balloon-expandable valves (BEVs) versus self-expanding valves (SEVs) exist. Methods and Results In a multicenter study, direct-invasive and echocardiography-derived transvalvular mean gradients obtained before and after TAVR were compared as well as post-TAVR and discharge echocardiographic mean gradients in BEVs versus SEVs in 808 patients. Pre-TAVR, there was good correlation (R=0.614; P<0.0001) between direct-invasive and echocardiography-derived mean gradients and weak correlation (R=0.138; P<0.0001) post-TAVR. Compared with post-TAVR echocardiographic mean gradients, both valves exhibit lower invasive and higher discharge echocardiographic mean gradients. Despite similar invasive mean gradients, a small BEV exhibits higher post-TAVR and discharge echocardiographic mean gradients than a large BEV, whereas small and large SEVs exhibit similar post-TAVR and discharge mean gradients. An ejection fraction <50% (P=0.028) and higher Society of Thoracic Surgeons predicted risk of mortality score (P=0.007), but not invasive or echocardiographic mean gradient ≥10 mm Hg (P=0.378 and P=0.341, respectively), nor discharge echocardiographic mean gradient ≥20 mm Hg (P=0.393), were associated with increased 2-year mortality. Conclusions Invasively measured and echocardiography-derived transvalvular mean gradients correlate well in aortic stenosis but weakly post-TAVR. Post-TAVR, echocardiography overestimates transvalvular mean gradients compared with invasive measurements, and poor correlation suggests these modalities cannot be used interchangeably. Moreover, echocardiographic mean gradients are higher on discharge than post-TAVR in all valves. Despite similar invasive mean gradients, a small BEV exhibits higher post-TAVR and discharge echocardiographic mean gradients than a large BEV, whereas small and large SEVs exhibit similar post-TAVR and discharge mean gradients. Immediately post-TAVR, elevated echocardiographic-derived mean gradients should be assessed with caution and compared with direct-invasive mean gradients. A low ejection fraction and higher Society of Thoracic Surgeons score, but not elevated mean gradients, are associated with increased 2-year mortality.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Hemodinâmica , Humanos , Desenho de Prótese , Resultado do Tratamento
5.
Bioeng Transl Med ; 3(1): 58-70, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29376134

RESUMO

The ability to perform laboratory testing near the patient and with smaller blood volumes would benefit patients and physicians alike. We describe our design of a miniaturized clinical laboratory system with three components: a hardware platform (ie, the miniLab) that performs preanalytical and analytical processing steps using miniaturized sample manipulation and detection modules, an assay-configurable cartridge that provides consumable materials and assay reagents, and a server that communicates bidirectionally with the miniLab to manage assay-specific protocols and analyze, store, and report results (i.e., the virtual analyzer). The miniLab can detect analytes in blood using multiple methods, including molecular diagnostics, immunoassays, clinical chemistry, and hematology. Analytical performance results show that our qualitative Zika virus assay has a limit of detection of 55 genomic copies/ml. For our anti-herpes simplex virus type 2 immunoglobulin G, lipid panel, and lymphocyte subset panel assays, the miniLab has low imprecision, and method comparison results agree well with those from the United States Food and Drug Administration-cleared devices. With its small footprint and versatility, the miniLab has the potential to provide testing of a range of analytes in decentralized locations.

6.
Indian Heart J ; 67(4): 381-4, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26304575

RESUMO

Supporting catheters in percutaneous stenting of anatomically difficult coronary lesions are utilized by interventional cardiologists. The GuideZilla guide extension catheter is designed for deep seating in coronary arteries to provide extra guidance support for equipment delivery during difficult coronary interventions or for coaxial alignment in tortuous vessels. There are limited GuideZilla-related complications reported in the literature. We present a challenging case of a left main and left anterior descending artery dissection, complicated with stent stripping off the delivery balloon by the GuideZilla support catheter.


Assuntos
Cateteres Cardíacos/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Procedimentos Endovasculares/efeitos adversos , Complicações Pós-Operatórias , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Procedimentos Endovasculares/instrumentação , Falha de Equipamento , Humanos , Masculino
7.
J Vasc Surg ; 48(2): 407-12, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18515036

RESUMO

OBJECTIVE: This prospective study determined the incidence of signs and symptoms of chronic venous disease and recurrent venous thrombotic events (VTE) in relation to the location and extent of the initial venous thrombus. METHODS: A first episode of acute deep vein thrombosis (DVT) occurred in 120 lower extremities of 105 patients (59 men; mean age, 54 years [range, 23-82 years]). Patients who presented with pain, swelling, or signs and symptoms of pulmonary embolism of <10 days were included. The DVT was diagnosed with duplex ultrasound (DUS) imaging. Patients were grouped by those having thrombosis in one venous segment (group A) or multiple levels (group B). Patients were treated with heparin and warfarin. Patients with at least 1-year of follow-up with clinical and DUS were included. RESULTS: No difference was found in the duration of signs and symptoms at presentation. The median follow-up was 3.4 years (range, 1.2-7 years). More symptomatic limbs were seen in group B (71 of 79) compared with group A (21 of 41; P < .001). Post-thrombotic syndrome (PTS) was more advanced in group B vs group A, including the prevalence of skin damage and ulceration (61 of 79 vs 26 of 41, P < .001; 29 of 79 vs 6 of 41, P = .019, respectively). Limbs with calf DVT that had focal thrombosis were most often asymptomatic. Calf thrombosis in patients with proximal DVT produced the highest prevalence of PTS. Venous claudication was exclusively found in group B and was present only when iliac veins were involved. Recurrent thrombosis had a trend for a higher prevalence in group B (5 of 41 vs 16 of 79, P = .39). Reflux, obstruction, or a combination of the two were more common in group B (61 of 79) vs group A (15 of 41; P < .0001). Limbs with both reflux and obstruction were more likely to develop skin damage (group A, 5 of 6 vs 1 of 35, P < .0001; group B, 24 of 29 vs 5 of 50, P < .0001). CONCLUSIONS: Recurrent thrombosis and skin damage is more likely to develop in patients with multiple sites of thrombosis than in those with thrombosis in a single vein segment. Patients with reflux and obstruction presented more skin damage than those with reflux or obstruction alone. Involvement of the calf veins in the presence of proximal vein thrombosis increased the likelihood for PTS.


Assuntos
Síndrome Pós-Trombótica/fisiopatologia , Embolia Pulmonar/fisiopatologia , Trombose Venosa/fisiopatologia , Doença Aguda , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Doença Crônica , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Síndrome Pós-Trombótica/diagnóstico por imagem , Síndrome Pós-Trombótica/epidemiologia , Prevalência , Probabilidade , Estudos Prospectivos , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/epidemiologia , Recidiva , Medição de Risco , Índice de Gravidade de Doença , Distribuição por Sexo , Ultrassonografia Doppler Dupla , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...